    BS 5266 Logbook Requirements

    Emergency Lighting Logbook — What to Record and Who Keeps It

    BS 5266-1 requires an emergency lighting logbook to be maintained for every installation — recording monthly tests, annual inspections, defects, and maintenance history. FireCert replaces paper logbooks with a structured digital record per building, always accessible, always complete.

    See how it works
    Monthly Test RecordsAnnual Test HistoryDefect LoggingPhotometric RecordsBS 5266-1:2025Per Building

    Is an Emergency Lighting Logbook a Legal Requirement?

    Yes. BS 5266-1 mandates that an emergency lighting logbook must be maintained for every installation. The logbook must be kept on-site and made available for inspection by enforcing authorities at any time.

    Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person for any non-domestic premises has a legal duty to ensure fire safety equipment — including emergency lighting — is maintained in efficient working order. The logbook is the primary evidence that this duty is being met.

    BS 5266-1:2025 strengthened the guidance on record keeping. Alongside monthly and annual test results, the logbook is where photometric performance verification data belongs — a check the 2025 edition recommends at intervals not exceeding five years. In practice the logbook has become a more comprehensive compliance document than ever before.

    Failure to maintain a proper emergency lighting logbook — or being unable to produce it for an enforcing authority — can result in enforcement notices, fines, or prosecution under the Fire Safety Order.

    The logbook must be kept on-site at all times and be available for inspection. A logbook that only exists on a personal device, in someone's email, or cannot be located during an inspection provides no compliance protection.

    What Must an Emergency Lighting Logbook Contain?

    BS 5266-1 specifies the minimum content an emergency lighting logbook must record. FireCert captures all of it in a structured digital format per building.

    Installation Records

    System Installation Details

    The logbook must record details of the emergency lighting installation at the time of commissioning — including the completion certificate reference, the installer's details, the number and type of luminaires installed, the photometric design data, and the date of installation.

    Luminaire Schedule

    A complete schedule of every emergency luminaire in the building — location, type (maintained or non-maintained, self-contained or central battery), fitting reference, and rated duration. This forms the baseline record against which all test results are logged.

    Commissioning Certificate Reference

    The logbook must reference the completion certificate issued at commissioning. If the installation pre-dates the current contractor, the existing site compliance certificate serves this purpose.

    Ongoing Records

    Monthly Functional Test Results

    A record of every monthly functional test — date, person carrying out the test, result for each luminaire (pass or fail), and any remedial actions taken. Every month must be accounted for. Gaps in monthly records are a common finding during enforcing authority inspections.

    Annual Inspection & Test Results

    The results of each annual full-duration test, cross-referenced to the Periodic Inspection and Testing Certificate issued by the contractor. Records must include the test duration, any luminaires that failed during the test, and the date the next inspection is due.

    Defects and Remedial Actions

    Any defects identified — whether during monthly tests, annual inspections, or routine visits — must be recorded with the date found, severity, remedial action taken, and date resolved. Unresolved defects must remain open in the logbook until rectified.

    Five-Year Photometric Records

    New in BS 5266-1:2025

    BS 5266-1:2025 recommends photometric performance verification at intervals not exceeding five years. Where it is carried out, keep the measurement data, the comparison against the design criteria, and confirmation that illumination levels still reflect the design intent.

    Paper Logbooks vs FireCert Digital Records

    Paper logbook

    • Can be lost, damaged, or left on-site when needed remotely
    • No structured format — entries vary between engineers
    • No alerts when monthly tests are overdue or missed
    • Cannot be accessed by the contractor without visiting site
    • Hard to search historical records during an inspection
    • Certificates stored separately with no link to logbook entries

    FireCert

    • Digital records always accessible from any device, anywhere
    • Structured monthly test records with date, tester, and result per luminaire
    • Automated reminders when monthly or annual tests are due
    • Contractor and client both have access — no site visit required for records
    • Full searchable history per building, instantly available for inspection
    • Annual certificates linked directly to the relevant logbook entries

    How FireCert Works as Your Digital Emergency Lighting Logbook

    Structured monthly test records

    Engineers log monthly functional test results against each luminaire in the building's asset register. Pass, fail, and notes are recorded per luminaire — creating a complete structured record that mirrors what BS 5266-1 requires in the logbook.

    Automated test reminders

    FireCert tracks monthly and annual test due dates per building and sends automated reminder emails when tests are approaching or overdue. You never need to manually chase test dates again.

    Certificates linked to logbook entries

    Annual Periodic Inspection and Testing Certificates are generated directly from test data and linked to the building's logbook record. The connection between the certificate and the underlying test data is permanent and auditable.

    Client access via portal

    Building owners and responsible persons can access their emergency lighting logbook records through FireCert's client portal — without needing to call the contractor or wait for emailed PDFs.

    Hartley Business Centre — Emergency Lighting Logbook

    Jan 2026·Monthly Test

    48/48 pass

    Complete
    Feb 2026·Monthly Test

    47/48 pass — 1 defect logged

    Defect Open
    Mar 2026·Monthly Test

    48/48 pass — defect resolved

    Complete
    Apr 2026·Annual Test

    Full duration — certificate issued

    Certified
    Apr 2031·Photometric Check

    5-year verification due

    Scheduled

    Who Is Responsible for the Emergency Lighting Logbook?

    The responsible person for the premises — typically the building owner, employer, or facilities manager — is legally responsible for ensuring the emergency lighting logbook is maintained. This duty cannot be delegated away entirely, even if a contractor carries out the testing.

    In practice, the contractor plays a key role. When a contractor carries out the annual full-duration test, they must issue a certificate and ensure the logbook is updated with the results. Monthly tests are typically carried out by building staff — but the contractor is often expected to set up the logbook and train the responsible person on how to complete monthly entries.

    FireCert makes this division of responsibility clear and manageable. Contractors can update the logbook remotely after each visit. Building staff can log monthly test results directly. The responsible person can view the complete record at any time through the client portal.

    Logbook responsibilities at a glance:

    • Contractor — issues completion certificate, updates logbook after annual test, logs defects and remedials
    • Building staff — carries out and logs monthly functional tests
    • Responsible person — ensures testing happens, logbook is maintained, and records are available for inspection
    • FireCert — keeps all records in one place, accessible to all parties, with automated reminders so nothing is missed

    Frequently Asked Questions

    Yes. BS 5266-1 mandates that an emergency lighting logbook must be maintained for every installation and kept on-site at all times. Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person is legally required to maintain records demonstrating that fire safety equipment — including emergency lighting — is properly maintained and tested. Failure to produce a logbook during an enforcing authority inspection can result in enforcement action.

    The logbook must record: details of the installation and commissioning certificate; a schedule of all luminaires; the results of every monthly functional test; the results of every annual full-duration test and cross-reference to the certificate issued; any defects found and remedial actions taken; and, where carried out, photometric performance verification results — which BS 5266-1:2025 recommends at intervals not exceeding five years.

    Records should be kept for the lifetime of the installation. There is no fixed minimum retention period specified in BS 5266-1, but enforcing authorities can request historical records going back many years. Digital records in FireCert are retained indefinitely and are always accessible.

    Monthly functional tests can be carried out by any trained building staff member — they do not require a specialist contractor. However, the responsible person must ensure tests happen every month and that results are properly recorded in the logbook. FireCert sends automated reminders when monthly tests are due and provides a structured record for logging results.

    Yes. BS 5266-1 does not require a physical paper logbook — it requires that records are maintained and accessible. A digital logbook that captures all required information and can be accessed on-site satisfies the standard's requirements. FireCert's digital logbook records all required information in a structured format, accessible from any device.

    If an enforcing authority — such as the Fire and Rescue Service — inspects a premises and a logbook cannot be produced, this is treated as evidence that the legal duty to maintain emergency lighting records has not been met. This can result in an enforcement notice requiring records to be established, or in more serious cases, prosecution under the Fire Safety Order.

    Yes. FireCert tracks monthly and annual test due dates for every building and sends automated reminder emails when tests are approaching or overdue. Your compliance dashboard shows live testing status across all buildings, making it easy to manage testing schedules across a portfolio.

    FireCert starts from £79/month for up to 2 engineers (Solo); Team is £149/month for up to 5 engineers and Business £279/month for up to 15, with office users included. Every plan includes unlimited buildings and certificates across all disciplines including emergency lighting, fire alarms, extinguishers, fire doors, dry risers, AOV / smoke control, intruder, CCTV, access control, PAT testing and electrical. No contracts, cancel anytime.

    Replace Your Paper Logbook With a Digital Compliance Record

    FireCert keeps your emergency lighting logbook structured, up to date, and always accessible — for contractors, building staff, and responsible persons.

    See certificate software

    What contractors say

    Loved by UK fire & security contractors

    Highly recommended.

    I have asked for many changes and got to say never known service like it. Absolutely amazing speed and quality. Nothing has been a problem. Excellent product. Excellent service.

    WR
    Wayne Rose
    Fire & Security Contractor