Last updated: June 2026

    BS 5839-1 Fire Alarm Logbook

    Fire Alarm Logbook — What to Record and Who Keeps It

    BS 5839-1 requires a fire alarm logbook to be maintained for every commercial fire alarm system — recording weekly call point tests, service visit results, defects, and system changes. FireCert replaces paper logbooks with a structured digital record per building, always accessible, always complete, and updated for BS 5839-1:2025.

    See how it works
    Weekly Test RecordsService Visit HistoryDefect LogCertificate ArchiveBS 5839-1:2025Per Building

    Is a Fire Alarm Logbook a Legal Requirement?

    Yes. BS 5839-1 requires a logbook to be maintained for every commercial fire alarm system and kept on-site at all times. The logbook is the primary record of how the system has been tested and maintained throughout its lifetime.

    Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person for any non-domestic premises is legally required to ensure fire alarm systems are maintained in efficient working order and that adequate records are kept. The logbook is the evidence that this duty is being met. Enforcing authorities — including the Fire and Rescue Service — will ask to see it during inspections.

    BS 5839-1:2025 strengthened logbook requirements compared to the 2017 edition. All deviations from the standard must now be explicitly documented in the logbook. Zone charts must be verified at every maintenance visit and any discrepancies recorded. False alarms must be logged with the category of false alarm assigned. The logbook has become a more comprehensive compliance document than ever before.

    Failure to maintain a logbook — or inability to produce it during an inspection — is treated as evidence that the legal duty to maintain records has not been met. This can result in enforcement notices or prosecution under the Fire Safety Order.

    The logbook must be kept on-site at all times and available for inspection on demand. A logbook that only exists in someone's email, on a personal device, or cannot be located during an inspection provides no compliance protection — regardless of whether the tests were actually carried out.

    What Must a Fire Alarm Logbook Contain?

    BS 5839-1 specifies the minimum content a fire alarm logbook must record. FireCert captures all of it in a structured digital format per building.

    Weekly Call Point Test Records

    BS 5839-1 requires a manual call point to be tested every week in commercial buildings — a different one each week so all are covered over time. The logbook must record the date of each test, which call point was tested, who carried out the test, and the result. Gaps in weekly records are a common finding during enforcing authority inspections and can indicate non-compliance with the maintenance regime. FireCert tracks weekly test due dates and provides a structured record for logging results.

    Service Visit Records

    The results of every six-monthly service visit must be recorded in the logbook — including the date, the engineer's name and company, all devices tested, test results, and any defects found. The logbook entry must cross-reference the formal maintenance certificate issued after the visit. FireCert links every service visit record directly to the certificate issued, creating a permanent, searchable history.

    Defects and Remedial Actions

    Any defects identified — whether during weekly tests, service visits, or at any other time — must be recorded in the logbook with the date found, the device affected, the nature of the fault, and the remedial action taken. Defects must remain open in the logbook until they are formally resolved. Under BS 5839-1:2025, the category of false alarm must also be recorded for every unwanted alarm signal.

    System Changes and Modifications

    Whenever changes are made to the fire alarm system — adding or relocating devices, upgrading the panel, changing zone configurations — this must be recorded in the logbook alongside the modification certificate reference. The logbook must reflect the current state of the system at all times, which is why an up-to-date asset register is essential alongside it.

    False Alarm Records

    BS 5839-1:2025 introduced a requirement to record and categorise every false alarm. The logbook must record the date, time, and location of activation, the category of false alarm (equipment false alarm, unwanted alarm, or unknown), and any investigation carried out. Where the false alarm rate triggers a preliminary or in-depth investigation under the standard, that investigation must also be documented.

    Certificate References

    The logbook must reference the commissioning certificate issued when the system was installed, and each subsequent maintenance certificate issued after every service visit. The certificates themselves don't need to be kept in the logbook, but the reference numbers and dates must be recorded so the complete certification history can be traced.

    Deviations from BS 5839-1

    New in BS 5839-1:2025

    BS 5839-1:2025 now requires all deviations from the standard to be explicitly documented in the logbook — for example, where detector placement doesn't fully meet the standard's recommendations due to building constraints, or where a variation has been agreed with the enforcing authority. This is a new requirement that makes the logbook a more active compliance document than in previous editions.

    Paper Logbooks vs FireCert Digital Records

    Paper logbook

    • Can be lost, damaged, or left on-site when needed remotely
    • No structured format — entries vary between engineers and visits
    • No alerts when weekly tests are overdue or missed
    • Cannot be accessed by the contractor without visiting the site
    • Certificates stored separately with no link to logbook entries
    • Hard to search historical records during an inspection
    • No way to demonstrate that all required fields have been completed

    FireCert

    • Digital records accessible from any device, anywhere
    • Structured weekly test records with date, tester, call point, and result
    • Automated reminders when weekly tests or service visits are due
    • Contractor and client both have access — no site visit required for records
    • Service visit records linked directly to the maintenance certificate issued
    • Complete searchable history per building, instantly available for inspection
    • False alarm records with category assignment as required by BS 5839-1:2025

    How FireCert Works as Your Digital Fire Alarm Logbook

    Structured weekly test records

    Building staff or engineers log weekly call point test results in FireCert — date, call point tested, tester name, and result. The record is structured and searchable, satisfying BS 5839-1's weekly test requirements.

    Automated reminders

    FireCert tracks weekly test due dates and six-monthly service visit due dates per building. Automated reminder emails are sent when tests or visits are approaching or overdue.

    Service visits linked to certificates

    Every service visit record in FireCert is linked to the maintenance certificate issued after that visit. The connection between the logbook entry and the certificate is permanent and auditable.

    Client access via portal

    Building managers and responsible persons can access their fire alarm logbook records through FireCert's client portal — without needing to contact the contractor or wait for emailed documents.

    Meridian Tower — Fire Alarm Logbook

    07 Apr 2026·Weekly test

    CP-12 Zone 3

    Pass
    31 Mar 2026·Weekly test

    CP-08 Zone 2

    Pass
    24 Mar 2026·Weekly test

    CP-04 Zone 1

    Defect logged
    15 Mar 2026·Six-monthly service

    All devices

    Certificate issued
    10 Mar 2026·False alarm

    Zone 5 — kitchen

    Equipment false alarm

    Who Is Responsible for the Fire Alarm Logbook?

    The responsible person for the premises — typically the building owner, employer, or facilities manager — is legally responsible for ensuring the fire alarm logbook is maintained. This duty cannot be fully delegated, even if a contractor carries out the testing.

    In practice, responsibility is shared. Weekly call point tests are typically carried out by building staff — a designated person who is trained to operate the test key and record results. Six-monthly service visits are carried out by the fire alarm contractor, who updates the logbook with the visit results and issues the maintenance certificate. The responsible person must ensure both are happening and that records are being kept correctly.

    FireCert makes this division clear and manageable. Contractors can update the logbook remotely after each service visit. Building staff can log weekly test results directly. The responsible person can view the complete record at any time through the client portal — and produce it instantly if an enforcing authority inspection requires it.

    Logbook responsibilities:

    • Building staff — carry out and log weekly call point tests
    • Fire alarm contractor — updates logbook after every service visit, logs defects and remedials, issues and references maintenance certificates
    • Responsible person — ensures testing happens, logbook is maintained, and records can be produced for inspection
    • FireCert — keeps all records in one place, accessible to all parties, with automated reminders so nothing is missed

    Frequently Asked Questions

    Yes. BS 5839-1 requires a fire alarm logbook to be maintained for every commercial fire alarm system and kept on-site at all times. Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person is legally required to maintain records demonstrating that fire alarm systems are properly maintained and tested. Failure to produce a logbook during an enforcing authority inspection can result in enforcement action.

    The logbook must record: weekly call point test results; the results of every six-monthly service visit cross-referenced to the maintenance certificate; defects found and remedial actions taken; system modifications cross-referenced to the modification certificate; false alarm records with category assignment (required under BS 5839-1:2025); and all deviations from BS 5839-1 (a new requirement under the 2025 edition).

    Every week. BS 5839-1 requires a different call point to be tested each week so all are covered over time. Each test must be recorded in the logbook with the date, which call point was tested, the tester's name, and the result. Gaps in weekly records are a common finding during enforcing authority inspections.

    Weekly call point tests can be carried out by designated building staff — they do not require a specialist fire alarm engineer. However, the responsible person must ensure tests happen every week and results are properly recorded. FireCert sends automated reminders when weekly tests are due and provides a structured record for logging results.

    Yes. BS 5839-1 requires that records are maintained and accessible — it does not specify that a physical paper logbook must be used. A digital logbook that captures all required information and can be accessed on-site satisfies the standard's requirements. FireCert's digital logbook records all required information in a structured format, accessible from any device.

    BS 5839-1:2025 introduced several changes affecting logbook requirements: all deviations from the standard must now be explicitly documented; false alarms must be recorded with a category assigned (equipment false alarm, unwanted alarm, or unknown); zone charts must be verified at every maintenance visit and discrepancies recorded; and the false alarm rate must be calculated and investigations documented where thresholds are exceeded.

    Yes. FireCert tracks weekly test due dates per building and sends automated reminder emails when tests are due. Your dashboard shows the current testing status across all buildings in your portfolio.

    FireCert starts from £79/month for up to 2 engineers (Solo); Team is £149/month for up to 5 engineers and Business £279/month for up to 15, with office users included. Every plan includes unlimited buildings, records and certificates. No contracts, cancel anytime.

    Replace Your Paper Fire Alarm Logbook With a Digital Compliance Record

    FireCert keeps your fire alarm logbook structured, up to date, and always accessible — for contractors, building staff, and responsible persons — updated for BS 5839-1:2025.

    See certificate software

    What contractors say

    Loved by UK fire & security contractors

    Highly recommended.

    I have asked for many changes and got to say never known service like it. Absolutely amazing speed and quality. Nothing has been a problem. Excellent product. Excellent service.

    WR
    Wayne Rose
    Fire & Security Contractor