    PD 6662 Certificate Software

    Intruder Alarm Certificate Software for UK Security Engineers

    FireCert generates every intruder alarm certificate required under PD 6662 and BS EN 50131 — from initial design through to ongoing maintenance — with structured workflows that capture system grade, notification option, panel hierarchy, detector schedules, and all required compliance records.

    See all disciplines
    Design & SurveyInstallationCommissioningMaintenancePD 6662:2017BS EN 50131Grades 1-4
    Also covers:CCTVAccess ControlFire AlarmEmergency LightingExtinguishersFire DoorsDry RisersAOVPAT TestingElectrical

    What is PD 6662?

    PD 6662:2017 is the primary UK standard for the design, installation, commissioning, and maintenance of intruder and hold-up alarm systems. It is an umbrella document that calls up the European BS EN 50131 series of standards and applies them within the UK context — making it the benchmark that insurers, NSI, SSAIB, and police forces use when assessing alarm systems.

    PD 6662 defines four grades of alarm system (Grade 1 to Grade 4) based on the risk level of the premises and the resilience required against attack. It also specifies notification options — how the alarm signals to an alarm receiving centre (ARC) — from basic local alarms through to fully monitored Grade 4 systems with confirmed alarm signalling under BS 8243.

    Every security engineer installing or maintaining intruder alarm systems in the UK is required to produce formal documentation at each stage of the system's lifecycle — from the initial design survey through to ongoing maintenance visits. These documents form the compliance record that insurers and approvals bodies require.

    PD 6662 System Grades:

    • Grade 1 — Very low risk — basic residential, no insurance requirement
    • Grade 2 — Low to medium risk — residential and small commercial with insurance
    • Grade 3 — Medium to high risk — commercial premises, higher insurance requirements
    • Grade 4 — High risk — highest security, police response, monitored 24/7

    FireCert captures the system grade and notification option on every certificate.

    Intruder Alarm Certificate Types FireCert Generates

    PD 6662 and BS EN 50131 require formal documentation at every stage of an intruder alarm system's lifecycle. FireCert generates all required certificate types with structured workflows that ensure the correct information is captured.

    Design & Survey Certificate

    PD 6662 / BS EN 50131-1

    Issued before installation begins. Documents the security risk assessment, proposed system grade, notification option, detector placement, and zone layout. The design certificate is the foundation for the installation and is required by approvals bodies and insurers.

    Installation Certificate

    PD 6662 / BS EN 50131-1

    Issued on completion of the physical installation. Confirms the system has been installed in accordance with the approved design, the correct grade of equipment has been used, and all wiring and connections comply with the standard.

    Commissioning Certificate

    PD 6662 / BS EN 50131-1

    Required before the system is handed over to the client. Confirms the complete system has been programmed, tested, and verified as operating correctly — including all detectors, panels, sounders, and signalling equipment.

    Maintenance Certificate

    DD 263 / PD 6662

    Issued after every maintenance visit. Documents all tests carried out, any faults found, remedial actions taken, and confirmation the system continues to meet its specified grade. PD 6662 requires either one or two maintenance visits per year depending on system grade.

    What FireCert Captures for Intruder Alarm Compliance

    Intruder alarm certificates require more structured system data than most other disciplines. FireCert's intruder alarm workflows are built around the specific data requirements of PD 6662 — capturing everything needed for approvals body submissions and insurance compliance.

    System grade and notification option

    Every certificate captures the system grade (1-4) and notification option (A, B, C, D, T, or X) — the core compliance data that insurers and approvals bodies require on every document.

    Panel and expander hierarchy

    FireCert records the full panel structure — control panel make and model, expanders, keypads, and communicators — structured as a hierarchy within the building's asset register.

    Zone and detector schedule

    Every zone is recorded with its type, detectors assigned, wiring configuration, and test results. The detector schedule populates directly into the commissioning and maintenance certificate workflows.

    Programming types and settings

    Key programming details — entry/exit delays, alarm confirmation type, inhibit and isolation settings, and user code structure — are captured as part of the commissioning record.

    Wiring types and cable records

    FireCert records the wiring type (wired, wireless, or hybrid) and cable specification per zone — creating a permanent installation record that maintenance engineers can reference on future visits.

    Maintenance test results

    Every maintenance visit logs test results per detector and zone — walk test results, sounder tests, power supply checks, battery condition, and signalling tests — building a complete service history per system.

    Intruder Alarm Maintenance — What PD 6662 Requires

    DD 263 (called up by PD 6662) specifies the maintenance requirements for intruder alarm systems. The frequency of maintenance visits depends on the grade of the system — and a formal maintenance certificate must be issued after every visit.

    One maintenance visit per year

    Grade 1 & 2 systems

    Grade 1 and Grade 2 systems require a minimum of one maintenance visit per year. Each visit must be documented with a formal maintenance certificate recording all tests carried out and the current condition of the system.

    Two maintenance visits per year

    Grade 3 & 4 systems

    Grade 3 and Grade 4 systems require a minimum of two maintenance visits per year — typically at six-monthly intervals. FireCert tracks both visit due dates and sends automated reminders when visits are approaching or overdue.

    FireCert tracks maintenance due dates for every intruder alarm system in your portfolio — regardless of grade — and sends automated reminder emails so nothing goes overdue.

    Security and Fire Compliance in One Platform

    Most security engineers don't just install intruder alarms. They also install CCTV, access control, and increasingly work alongside fire alarm contractors on the same sites. Managing these disciplines across different systems — separate software, separate paper records, separate client communications — creates unnecessary complexity.

    FireCert is built around the building, not the discipline. Every site has one building record, one asset register, and one client portal — regardless of how many disciplines you manage there. When you visit a site for an intruder alarm maintenance, your CCTV records and access control system data are right there alongside it.

    And because FireCert also covers fire alarm, emergency lighting, and extinguisher compliance, contractors who work across both fire and security disciplines can manage everything in one structured platform — giving clients a complete compliance picture in one portal.

    Fire AlarmBS 5839-1
    Domestic FireBS 5839-6
    Emergency LightingBS 5266
    Fire ExtinguishersBS 5306
    Intruder AlarmPD 6662
    Fire DoorsFire Safety Regs 2022
    Dry RisersBS 9990
    AOV / Smoke ControlBS 7346-8
    CCTVBS EN 62676
    Access ControlBS EN 60839
    PAT TestingIET CoP
    ElectricalBS 7671

    FireCert vs Paper Records and Generic Job Management Tools

    Paper records and generic tools

    • Design surveys stored as Word documents with no structure
    • Panel and zone data retyped on every maintenance certificate
    • No tracking of whether Grade 3/4 systems have had both annual visits
    • Maintenance certificates manually typed after every visit
    • No link between intruder alarm records and CCTV or fire alarm compliance
    • Clients have no structured view of their system compliance history

    FireCert

    • Structured design records capturing grade, notification option, and full panel hierarchy
    • Panel, zone, and detector data prefills into maintenance certificate workflows
    • Maintenance visit tracking per grade — with automated reminders for Grade 3/4 two-visit requirements
    • Maintenance certificates generated from test data captured on-site
    • Intruder alarm records share building data with CCTV, access control, and fire disciplines
    • Client portal gives building owners complete visibility of all compliance records

    Frequently Asked Questions

    Intruder alarm certificate software generates the formal documents required at each stage of an intruder alarm system's lifecycle under PD 6662 — including design and survey certificates, installation certificates, commissioning certificates, and maintenance certificates. FireCert is built specifically for UK security engineers, with structured workflows that capture all required PD 6662 compliance data.

    FireCert generates design and survey certificates, installation certificates, commissioning certificates, and maintenance certificates — covering every stage of the intruder alarm lifecycle from initial survey through to ongoing service visits.

    Yes. FireCert captures the system grade (1-4) and notification option on every certificate. The certificate workflows are structured to capture the correct information for each grade level.

    DD 263 (called up by PD 6662) requires Grade 1 and Grade 2 systems to have a minimum of one maintenance visit per year, and Grade 3 and Grade 4 systems to have a minimum of two visits per year. FireCert tracks maintenance due dates per system and sends automated reminders when visits are approaching or overdue.

    Yes. FireCert covers intruder alarms, CCTV, and access control alongside fire alarm, emergency lighting, extinguisher, fire door, dry riser, AOV, PAT and electrical compliance — all within the same platform with shared building records, asset registers, and client portal.

    Yes. FireCert records the full panel structure — control panel, expanders, keypads, and communicators — plus zone types, detector schedules, wiring types, and programming details. This data populates directly into maintenance certificate workflows so engineers don't retype system information on every visit.

    Generic job management tools are built for scheduling and invoicing — PD 6662 compliance record keeping is not their focus. FireCert is built specifically around fire and security compliance, with structured data capture for intruder alarm systems, automatic population of certificate workflows from asset register data, and a building-centric model that links all disciplines together.

    FireCert starts from £79/month for up to 2 engineers (Solo); Team is £149/month for up to 5 engineers and Business £279/month for up to 15, with office users included. Every plan includes unlimited buildings and certificates across all disciplines including intruder alarms, CCTV, access control, fire alarms, emergency lighting, extinguishers, fire doors, dry risers, AOV / smoke control, PAT testing and electrical. No contracts, cancel anytime.

    Start Managing Intruder Alarm Compliance Properly

    Replace paper records and generic tools with a structured compliance platform built specifically for UK security engineers — covering intruder alarms, CCTV, access control, and fire disciplines in one place.

    View Sample Certificate