BS 5266 Certificate Software
Emergency Lighting Certificate Software — Built for UK Contractors
FireCert generates every BS 5266 emergency lighting certificate type — completion, periodic inspection and testing — with structured workflows that capture luminaire-level data, test results, and defect records. Updated for BS 5266-1:2025.
What is BS 5266 Emergency Lighting?
BS 5266-1 is the British Standard code of practice for the emergency lighting of premises. It sets out the requirements for the design, installation, commissioning, and ongoing maintenance of emergency lighting systems — covering escape route lighting, open area anti-panic lighting, and high-risk task area lighting.
Emergency escape lighting is a legal requirement under the Regulatory Reform (Fire Safety) Order 2005 in England and Wales wherever a fire risk assessment identifies the need. BS 5266-1, alongside BS EN 50172 and BS EN 1838, is the recognised code of practice used to demonstrate compliance with that legal duty.
Every contractor installing, commissioning, or maintaining emergency lighting in non-domestic premises is required to issue the appropriate BS 5266 certificate — and to maintain a logbook of all monthly and annual test results for the lifetime of the installation.
BS 5266-1 was updated in 2025, recommending photometric performance verification at intervals not exceeding five years and expanding the guidance covering standby and local area lighting.
Emergency lighting is required in:
- All non-domestic premises with escape routes
- Offices, warehouses and industrial buildings
- Schools, colleges and universities
- Hotels, restaurants and licensed premises
- Hospitals, care homes and healthcare facilities
- Retail premises and shopping centres
- Any building where a fire risk assessment identifies the need
BS 5266 Emergency Lighting Certificate Types
BS 5266-1 defines specific certificate types for different stages of an emergency lighting installation. FireCert generates all of them, with structured workflows that ensure the correct information is captured every time.
Emergency Lighting Completion Certificate (Small)
BS 5266-1 Annex H
For new installations of up to 25 self-contained luminaires. Includes signed declarations of design, installation, and verification, along with photometric data and the test logbook reference. The most common certificate issued by contractors on smaller sites.
Emergency Lighting Completion Certificate (Large)
BS 5266-1 Annex H
For larger installations exceeding 25 luminaires. Requires full photometric design data, signed declarations from designer, installer and verifier, and a comprehensive luminaire schedule. FireCert captures all required sections in a structured workflow.
Periodic Inspection & Testing Certificate
BS 5266-1 Annex M / BS EN 50172
Issued after the annual full-duration test of an existing emergency lighting installation. Confirms all luminaires have been tested, the system continues to meet BS 5266-1 requirements, and records any deviations or defects found during testing.
Existing Site Compliance Certificate
BS 5266-1
Issued for existing installations where a full completion certificate was not originally provided. Confirms the current state of the installation and its compliance with BS 5266-1 at the time of inspection.
Emergency Lighting Testing Requirements
BS 5266-1 and BS EN 50172 require emergency lighting to be tested at three intervals. FireCert tracks all three and maintains the complete testing history for every building.
Monthly Functional Test
A short-duration test simulating mains failure. Each luminaire must illuminate and remain lit for the minimum period. Results are logged in the building's test record. FireCert tracks monthly test status per building so nothing goes unrecorded.
Short durationAnnual Full-Duration Test
A full rated-duration test — typically three hours — carried out annually. All luminaires must remain lit for the full duration. On completion, a Periodic Inspection and Testing Certificate is issued. FireCert generates this certificate directly from the test results captured on-site.
3-hour durationFive-Year Photometric Verification
Recommended by BS 5266-1:2025 at intervals not exceeding five years. Confirms that measured light output still reflects the original design criteria, with the results kept in the emergency lighting logbook. FireCert records and stores photometric verification data as part of the building's compliance history.
New in 2025How FireCert Handles Emergency Lighting Compliance
Structured certificate workflows
Step-by-step wizards guide engineers through every required section of the BS 5266 certificate — from photometric data through to signed declarations. Mandatory fields prevent incomplete certificates from being issued.
Luminaire-level asset register
Record every emergency luminaire per building — type, location, maintained or non-maintained, self-contained or central battery. Test results are logged against each luminaire for a complete testing history.
Automated test reminders
FireCert tracks monthly and annual test due dates per building and sends automated reminders so nothing goes overdue. Your dashboard shows which buildings are compliant, due, or overdue at a glance.
Locked PDFs with audit trail
Every certificate is hashed and locked on issue — preventing alterations after sign-off. Includes engineer signature capture, a QR verification code, and a full audit trail for enforcing authority submissions.
Who Issues Emergency Lighting Certificates?
Emergency lighting certificates are issued by contractors responsible for the design, installation, commissioning, or ongoing maintenance of emergency lighting systems. In the UK, this work is typically carried out by electrical contractors, fire alarm engineers, and specialist emergency lighting contractors.
Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person for a premises is legally required to ensure emergency lighting is maintained and tested. The contractor's certificates and logbook entries are the primary evidence that this duty has been met.
Many fire and security contractors carry out emergency lighting work alongside fire alarm installations — making FireCert's multi-discipline approach particularly valuable. Both fire alarm and emergency lighting certificates can be managed within the same platform, sharing building records and asset data.
FireCert is used by:
- Fire alarm contractors adding emergency lighting to their scope
- Electrical contractors working in commercial premises
- Facilities management companies maintaining multi-site portfolios
- Specialist emergency lighting contractors
- Building services engineers
FireCert vs Spreadsheets and Paper Logbooks
Spreadsheets & paper logbooks
- Monthly test records spread across paper logbooks and emails
- No central view of which buildings are compliant or overdue
- Certificates typed up manually after every visit
- No link between luminaire records and certificate data
- Easy to lose or alter — no tamper-proof audit trail
FireCert
- Monthly, annual and periodic verification records in one place
- Live compliance dashboard across every building
- Certificates generated directly from test data captured on-site
- Luminaire asset register feeds directly into certificate workflows
- Locked PDFs with QR verification — tamper-proof and auditable
Related Resources
Emergency Lighting Testing
Monthly checks, annual full-duration tests and what to record
Read moreEmergency Lighting Logbook
Digital logbooks for BS 5266 monthly and annual test records
Read moreBS 5266 Certificate Software
Standard-number keyword variant for BS 5266 emergency lighting certificates
Read moreFire Alarm Certificate Software
Complete fire and security compliance in one platform
Read moreFrequently Asked Questions
An emergency lighting certificate is a formal document issued by a qualified contractor to confirm that an emergency lighting installation has been designed, installed, commissioned, or tested in accordance with BS 5266-1. Different certificate types are required at different stages — completion certificates for new installations, and periodic inspection and testing certificates for ongoing maintenance.
A completion certificate is issued once when a new installation is commissioned. After that, a periodic inspection and testing certificate should be issued annually following the full-duration test. Monthly functional test results should be recorded in the building's emergency lighting logbook throughout the year.
A completion certificate is issued when a new emergency lighting installation is finished and commissioned — it confirms the system was designed, installed, and tested correctly. A periodic inspection and testing certificate is issued annually for existing installations, confirming the system continues to meet BS 5266-1 requirements.
The 2025 edition recommends photometric performance verification initially and at intervals not exceeding five years, confirming that the actual light output in the building still meets the original design criteria. It also expanded the guidance covering standby and local area lighting. FireCert records photometric verification data as part of each building's compliance history.
Yes. FireCert tracks monthly functional test due dates and annual full-duration test due dates per building. Automated reminders are sent when tests are approaching or overdue, and your dashboard shows live compliance status across all buildings.
Yes. FireCert covers BS 5839-1 fire alarm certificates, BS 5839-6 domestic fire alarm certificates, emergency lighting (BS 5266), fire extinguishers (BS 5306), fire doors, dry risers (BS 9990), AOV / smoke control (BS 7346), intruder alarms, CCTV, access control, PAT testing and electrical (BS 7671) — all within the same platform with shared building records.
FireCert starts from £79/month for up to 2 engineers (Solo); Team is £149/month for up to 5 engineers and Business £279/month for up to 15, with office users included. Every plan includes unlimited buildings and certificates across all supported disciplines. No contracts, cancel anytime.
Yes. FireCert is used by both fire alarm and electrical contractors. Emergency lighting work is commonly carried out by electricians working in commercial premises, and FireCert's BS 5266 workflows are built around how that work is actually done on-site.
Start Managing Emergency Lighting Certificates Properly
Replace paper logbooks, spreadsheets, and manually typed certificates with a structured compliance platform built for UK fire and electrical contractors.
What contractors say
Loved by UK fire & security contractors
Highly recommended.
I have asked for many changes and got to say never known service like it. Absolutely amazing speed and quality. Nothing has been a problem. Excellent product. Excellent service.
Related resources
Continue exploring the FireCert platform and the compliance topics most closely related to this page.
Emergency Lighting Testing
Monthly functional and annual duration workflows.
Read moreEmergency Lighting Logbook
Compliant BS 5266 log with every test evidenced.
Read moreDigital Emergency Lighting Log Book
Replace paper logs with a live cloud record.
Read moreFire & Security Software
The full FireCert platform for multi-discipline contractors.
Read moreFire & Security Management Software
Jobs, engineers, certificates and client portal in one.
Read moreFire Safety Compliance Software
Every discipline aligned to the relevant British Standard.
Read moreDry Riser Testing Software
Rising mains inspections and pressure tests alongside every other discipline.
Read moreFire Door Inspection Software
Door registers and inspection rounds alongside every other discipline.
Read more