Last updated: June 2026

    BS 5839-6 Certificate Software

    Domestic Fire Alarm Certificates — Done Properly

    BS 5839-6 is the British Standard for fire detection and alarm systems in domestic premises. FireCert generates every BS 5839-6 certificate type — covering Grade C, D and F systems — with structured workflows built for UK fire alarm and electrical contractors working in residential properties, HMOs and housing portfolios.

    Installation & CommissioningInspection & TestingGrade CGrade DGrade FHMOs & Housing
    Also covers:BS 5839-1Emergency LightingIntruderCCTVAccess ControlExtinguishersFire DoorsDry RisersAOVPAT TestingElectrical
    BS 5839-1
    Compliant
    Digital Certificates
    & PDF Export
    Asset Register
    Included
    QR Verification
    Built-in

    What is BS 5839-6?

    BS 5839-6 is the British Standard that governs the design, installation, commissioning, and maintenance of fire detection and alarm systems in domestic premises. Unlike BS 5839-1, which covers non-domestic buildings, BS 5839-6 applies specifically to dwellings — houses, flats, HMOs, sheltered housing, and any residential property.

    The standard classifies systems by grade (how the system is powered and controlled) and category (what areas of the property are protected). The most common grades in domestic properties are Grade D (mains-powered interlinked alarms) and Grade F (battery-powered alarms), though HMOs with higher risk profiles often require Grade C or Grade A systems.

    Fire alarm contractors and electricians working in residential properties are required to issue a BS 5839-6 certificate on completion of design, installation, and commissioning. Landlords, housing providers, and local authorities frequently request this certificate as proof of compliance.

    Who requires BS 5839-6 certificates:

    • Private landlords and letting agents
    • HMO landlords (mandatory for licensing)
    • Housing associations and local authorities
    • Sheltered and supported housing providers
    • Residential developers and builders
    • Fire alarm and electrical contractors

    BS 5839-6 Grades and Categories Explained

    Understanding grades and categories is essential for issuing correct BS 5839-6 certificates. FireCert's certificate workflows are structured around these classifications so engineers always capture the right information.

    Grades — how the system is powered

    APanel-based fire alarm system (designed to BS 5839-1)
    BMains-powered system with separate standby supply
    CMains-powered system with central control equipment
    D1Mains-powered alarms with tamper-proof battery backup
    D2Mains-powered alarms with user-replaceable battery backup
    EMains-powered alarms only (no standby)
    F1Battery-powered alarms (tamper-proof) interlinked
    F2Battery-powered alarms (user replaceable) interlinked

    Grades D and F are the most common in standard domestic properties. HMOs frequently require Grade C or above.

    Categories — what areas are protected

    LD1Full coverage (all areas)
    LD2Escape routes + high-risk rooms
    LD3Escape routes only
    PD1All rooms where persons sleep
    PD2Principal habitable rooms + circulation

    The appropriate category is determined by a fire risk assessment of the specific property.

    BS 5839-6 Certificate Types

    FireCert generates all required BS 5839-6 certificate types. Each workflow is structured around the relevant section of the standard, with mandatory fields for grade, category, system details, and device records.

    Design, Installation & Commissioning Certificate

    BS 5839-6 Annex E / Annex F

    The primary certificate for domestic fire alarm work. Issued on completion of a new installation, confirming the system has been designed, installed, and commissioned in compliance with BS 5839-6. Required for Grade C, D and F systems.

    Inspection & Testing Certificate

    BS 5839-6 Clause 23

    Issued after periodic inspection and testing of an existing domestic fire alarm system. Confirms all detectors, sounders, and interconnections have been tested and the system remains operational and compliant.

    Modification Certificate

    BS 5839-6

    Required when changes are made to an existing domestic system — adding detectors, changing grades, upgrading interconnection, or modifying the system layout in any way.

    Commissioning Certificate

    BS 5839-6

    Issued when commissioning is carried out separately from installation — for example where a developer installs the system and a separate contractor carries out commissioning and handover testing.

    How FireCert Handles BS 5839-6 Compliance

    Grade and category captured correctly

    Certificate workflows prompt engineers to specify the system grade and category for every property. The correct fields and checklists load automatically based on the grade selected.

    Property and system data prefilled

    Building details, system information, and device records pull through from the asset register. No retyping the same address and system details on every visit.

    Locked PDFs with verification

    Every certificate is hashed and locked on issue — preventing alterations after sign-off. Includes a QR verification code and full audit trail, giving landlords and local authorities confidence in the document.

    Client portal for landlords

    Landlords and housing providers see their certificates and compliance history, record their own weekly tests and report faults through FireCert's client portal — reducing admin calls and improving client retention.

    BS 5839-6 — Design, Installation & Commissioning

    Property14 Ashford Road, Sheffield
    GradeGrade D1
    CategoryLD2
    Detectors6 / 6
    Locked & verified

    HMO Fire Alarm Certificates — A Special Case

    Houses in Multiple Occupation (HMOs) have specific fire alarm requirements that go beyond standard domestic properties. FireCert is built to handle the more complex certificate requirements that HMO work demands.

    HMOs licensed under the Housing Act 2004 are required to have fire alarm systems that meet specific standards set out by the local housing authority. In most cases, HMOs require a Grade D or Grade C system with LD2 or LD1 category coverage — meaning detectors in all habitable rooms and escape routes.

    The certificate issued must confirm the grade, category, device locations, interconnection method, and test results for every detector and sounder in the property. FireCert's BS 5839-6 workflows capture all of this information in a structured format that satisfies housing authority requirements.

    FireCert for HMO compliance:

    • Grade and category recorded on every certificate
    • Device-level records for every detector and sounder
    • Full testing history per property
    • Client portal access for landlords and letting agents
    • Automated inspection reminders so nothing goes overdue
    • Professional locked PDF certificates for housing authority submissions

    FireCert vs Paper Certificates and Word Templates

    Paper & Word templates

    • Grade and category often missing or incorrect
    • No structured record of devices installed
    • Certificates look unprofessional and vary between engineers
    • No way to prove the certificate hasn't been altered
    • Landlords lose certificates — no central record

    FireCert

    • Grade, category and all system details captured in structured workflows
    • Full device register per property with testing history
    • Consistent, professional PDF certificates every time
    • Locked with verification QR — tamper-proof and auditable
    • Landlord portal gives clients permanent access to their certificates

    Frequently Asked Questions

    A BS 5839-6 certificate is a formal document issued by a fire alarm contractor or electrician to confirm that a domestic fire detection and alarm system has been designed, installed, and commissioned in accordance with BS 5839-6. It records the system grade, category, device locations, and test results, and serves as proof of compliance for landlords, housing authorities, and insurers.

    BS 5839-1 covers fire alarm systems in non-domestic buildings — offices, warehouses, schools, hotels and similar commercial premises. BS 5839-6 covers fire alarm systems in domestic premises — houses, flats, HMOs, and residential properties. FireCert generates certificates for both standards within the same platform.

    BS 5839-6 covers Grade A through to Grade F systems, with Grade D (mains-powered interlinked alarms) and Grade F (battery-powered alarms) being the most common in standard domestic properties. HMOs typically require Grade C or above. FireCert captures the grade and category on every certificate.

    Yes. HMOs licensed under the Housing Act 2004 are required to have compliant fire detection systems. A BS 5839-6 certificate from a qualified contractor provides the formal proof of compliance that housing authorities require. FireCert's workflows are structured to capture all the information needed for HMO certificate submissions.

    Yes. FireCert works on any device with a browser — phone, tablet, or laptop. Engineers can complete and issue certificates on-site without installing an app, and the completed PDF is immediately available for download or sharing with the client.

    Yes. FireCert covers both standards within the same platform. If your business works in both domestic and non-domestic premises, all your certificates, buildings, and asset registers are managed in one place.

    FireCert starts from £79/month for up to 2 engineers (Solo); Team is £149/month for up to 5 engineers and Business £279/month for up to 15, with office users included. Every plan includes unlimited buildings and certificates across all supported disciplines. No contracts, cancel anytime.

    Alongside fire alarm certificates, FireCert covers emergency lighting (BS 5266), fire extinguishers (BS 5306), fire doors, dry risers (BS 9990), AOV / smoke control (BS 7346), intruder alarms (PD 6662), CCTV, access control, PAT testing and electrical (BS 7671) — all within the same platform and shared building records.

    Start Issuing Proper Domestic Fire Alarm Certificates

    Replace paper forms and Word templates with a structured compliance platform built for UK fire alarm and electrical contractors working in residential and HMO properties.

    What contractors say

    Loved by UK fire & security contractors

    Highly recommended.

    I have asked for many changes and got to say never known service like it. Absolutely amazing speed and quality. Nothing has been a problem. Excellent product. Excellent service.

    WR
    Wayne Rose
    Fire & Security Contractor